Back to Top

1
Hi, Guest!

  LOKASI :  Jakarta Timur

  AKTIVITAS :  11/05/2022

BAGIKAN :   

Bagikan :
Kontak Kami  
Jual Alat Lab Penguji Lingkungan 2. Distributor Alat Castle Inc.Indonesia 3.Jual alat General Laboratory 4.Distributor Alat Delta Ohm Indonesia.5.Distributor B

GD-5208 Rapid Low Temp. Automatic Flash Point Tester brand gold

Update Terakhir
:
20 / 07 / 2021
Min. Pembelian
:
1 Unit

Harga

CALL
Bagikan
:
Dengan hormat, Kami PT.Mitra Katiga Sejahtera menjual alat laboratorium lingkungan.
I. STAPLEX, SHINAGAWA, NOVA GAS, DELTA OHM,LABTRON,TURNKEY INSTRUMENTS,HAZ DUST
E INSTRUMENT , EPAM-5000 ENVIRONMENTAL DEVICE , LABNICS,GOLD,AIRMETRIC,ASSEMBLAD,ANAPOL,ZHONGAN,KOMYO KITAGAWA,JXCT,TRAWAS
www.mitrakatigasejahtera.com

Detail GD-5208 Rapid Low Temp. Automatic Flash Point Tester Brand Gold

alat laboratorium lingkungan

GD-5208 Rapid Low Temp. Automatic Flash Point Tester

Introduction:

1. Our rapid low temperature automatic flash point tester is designed and made as per the National Standard of People’s Republic of China GB/T5208 “Test Methods for Flash Point (Rapid Equilibrium Closed Cup Method)”. It can be used in the field of petroleum, chemistry, paints, railway, aviation, power plant, inspection, military, and scientific research to determine flash point of petroleum products rapidly.

2. It is suitable to make closed cup flash point determination for paints, adhesives, solvents, petroleum, and relative petroleum products, the flash points of which are in the range of 30°C~50°C. It can also meet the requirements of ISO 1523 and ISO 3679.


Features:
1. It is designed as per GB/T5208 (Test Methods for Flash Point (Rapid Equilibrium Closed Cup Method)”. It can determine closed cup flash point at a low temperature rapidly.
2. It adopts semiconductor refrigeration device and cooling water refrigeration device. It is small, convenient and with rapid refrigeration speed.
3. It needs fewer sam
ples. The sample for each test is only 2 ml (For solid or semisolid sample, it is 4 ml);
4. The test can be automatically
completed excepting flame ignition. The test data can be automatically printed.


Specifications:

Power Supply

AC 220V±10%, 50 Hz

Flash point measurement range

-30~50°C

Measurement accuracy

Repeatability: less than 2°C

Reproducibility: less than 2°C

Temperature controlling accuracy

±0.5°C

Igniter

an electron igniter

Refrigeration type

It uses semiconductor for refrigeration (It connects to outer cooling water);

Power supply

AC 220V±10%, 50 Hz

Total power consumption

not more than 300 W

Ambient temperature

5°C~30°C

Relative humidity

30~80%